제목: 원자력발전소 공기구동 게이트 밸브의 성능예측결과와 정적진단시험 결과의 요구쓰러스트 비교

발간처: 한국전력기술주식회사

발간일: 2018.10.25

저자: 김봉환

내용

This study describes the comparison with performance prediction results and static diagnostic test results of the air-operated gate valves. The results of performance prediction methodology have been compared with static diagnostic test results for air-operated gate valves in NPPs. With the review of static diagnostic test data and performance prediction methodology results, it is concluded that the performance prediction methodology is conservative to predict a required thrust of the air-operated gate valves.Performance prediction methodology is a sufficiently conservative and safe method, since performance prediction was evaluated in previous studies in a more conservative method than dynamic diagnostic test result and this time more conservative than static diagnostic test results.

 